LMAXFOCKAE = integer (maximum L quantum number for accurate charge augmentation in HF routines)default: LMAXFOCKAE=-1
For accurate QP eigenvalues of systems with localized electrons,
the flag LMAXFOCKAE must be set. Usually VASP restores only the moments
of the all electron charge density on the
plane wave grid up to a certain radial quantum number.
If LMAXFOCKAE is set, the shape of the charge density is restored
accurately on the plane wave grid up to a typical plane wave
energy of 100 eV. Beyond that cutoff the polarizability is usually
very small (
), necessitating no accurate treatment.
Restoring the charge density on the plane wave grid with high precision allows to obtain accurate QP energies, even though the one-center-terms are not implemented in VASP for the GW case. The flag must be selected for GW calculations involving transition metals ( LMAXFOCKAE=4) and/or first row elements ( LMAXFOCKAE=2). See also Sec. 6.64.5.