ISMEAR = -5 | -4 | -3 | -2 | 0 | N SIGMA = width of the smearing in eV
Default | ||
ISMEAR | = | 1 |
SIGMA | = | 0.2 |
ISMEAR determines how the partial occupancies are set for each
wavefunction. For the finite temperature LDA SIGMA determines the
width of the smearing in eV.
ISMEAR:
There should be a tag
FERWE = f1 f2 f3 ....and for spin-polarized calculations
FERDO = f1 f2 f3 ...in the INCAR file supplying the partial occupancies for all bands and k-points. The band-index runs fastest. The partial occupancies must be between 0 and 1 (for spin-polarized and non-spin-polarized calculations).
SMEARINGS= ismear1 sigma1 ismear2 sigma2 ...must be present in the INCAR file, supplying different smearing parameters. IBRION is set to -1 and NSW to the number of supplied values. The first loop is done using the tetrahedron method with Blöchl corrections.
The method of Methfessel-Paxton (MP) also results in a very accurate
description of the total energy, nevertheless the width of the
smearing ( SIGMA) must be chosen carefully
(see also 7.4). Too large smearing-parameters might result
in a wrong total energy, small smearing parameters
require a large k-point mesh. SIGMA should be as large as possible keeping
the difference between the free energy and the total energy
(i.e. the term ' entropy T*S') in the OUTCAR file negligible (1 meV/atom).
In most cases and
leads to very similar results.
The method of MP is also the method of choice for large super cells, since
the tetrahedron method is not applicable, if less than three k-points are used.
Mind: Avoid using ISMEAR0 for semiconductors and insulators,
since this often leads to incorrect results (The occupancies of
some states might be larger or smaller than 1). For insulators use ISMEAR=0
or ISMEAR=-5.
The Gaussian smearing (GS) method leads in most cases also to reasonable results.
Within this method it is necessary to extrapolate from
finite SIGMA results to SIGMA=0 results. You can find an extra line
in the OUTCAR file ' energy( SIGMA )' giving the extrapolated results.
Large SIGMA values lead to a similar error as
the MP scheme, but in contrast to the MP scheme
one can not determine, how large the error due to the smearing is with
systematically reducing SIGMA.
Therefore the method of MP is more convenient than the
GS method. In addition, in the GS method forces and the stress tensor
are consistent with the free energy and not the energy for SIGMA
0.
Overall the Methfessel-Paxton is easier to use for metallic systems.
For further considerations on the choice for the smearing method see sections 7.4,8.6. To summarize, use the following guidelines:
For metals a sensible value is usually SIGMA= 0.2 (which is the default).